Surface DX Series

BET Surface Area Analyser

  • When fully optimized, up to 8 samples can be analyzed per hour across 4 stations.
  • Automatic Dewar elevator and valve status indicator lights streamline operation.
  • Compact, user-friendly design ideal for routine QC environments.

Download
brochure
   Request
quote

Gas Adsorption
Surface DX Series

● When fully optimized, up to 8 samples can be analyzed per hour across 4 stations.
● Automatic Dewar elevator and valve status indicator lights streamline operation.
● Compact, user-friendly design ideal for routine QC environments.

Introduction

The AMI-Surface DX Series offers a fully automated solution for BET surface area analysis using dynamic flow adsorption. Designed for high-throughput labs, it features four parallel analysis stations, enabling simultaneous testing and significantly reducing turnaround times.

Operating without a vacuum system, the AMI-Surface DX uses a dynamic flow (non-static) method that supports both single-point and multi-point BET analysis. This makes it ideal for quality control, R&D, and production environments, especially for low surface area materials. With reference comparison methods, adsorption peaks are detected rapidly and accurately—delivering precise results with exceptional speed.

Key Features

Patent of Invention

Accurate adsorption measurements based on sharp peak detection eliminate errors caused by incomplete desorption. Ideal for low surface area samples such as ternary materials and battery electrode materials. (Patent No. 20140320453.2)

Automatic Nitrogen Partial Pressure Control

Surface DX 400 is equipped with high-precision mass flow controllers to automatically regulate nitrogen partial pressure during BET surface area measurements. This ensures stable and accurate gas flow across the sample surface, delivering consistent and reliable adsorption results with minimal manual intervention.

Four Parallel Operating Analysis Stations

Run up to four samples at once with independently controlled stations. Achieve unmatched throughput with consistent test conditions and result repeatability better than ±1.0%.

Anti-Elutriation Technology

A built-in anti-contamination unit prevents sample particles from entering the instrument’s internal gas line, ensuring operational reliability and long-term cleanliness.

Optional Sample Preparation Unit

External sample preparation device with four-degas stations can remove adsorbed contaminants from surface and pores of samples with heating in flowing gas/vacuum. Temperature can be set and controlled from ambient to 400 ºC.

Low Form Dewar flask

Long lasting, high volume (1 L) Dewar flasks assure a constant thermal profile along the length of sample tubes during experiment.

AMI Instruments Surface DX Series

Fast, Sensitive Testing

Adsorption peak looks sharp, no trailing phenomenon, the change of nitrogen concentration caused by each sample adsorption is not diluted at all; the sensitivity of the sample test is greatly improved. The test efficiency is greatly improved under the condition of sufficient adsorption and the comparative test of four samples in one time only needs about 15 minutes.

AMI Instruments Surface DX Series

Software

The AMI-Surface DX software provides intuitive operation with real-time visualization of nitrogen and helium flow. During analysis, users can monitor adsorption activity dynamically, offering a clear understanding of test progress and conditions. Ideal for both novice and advanced users, the interface ensures reliable, traceable operation.

AMI Instruments Surface DX Series

Applications

Silcone Nitride

Specifications

Category Specification
Model Surface DX
Principle Low temperature nitrogen adsorption, dynamic method
Method Reference method
Single point BET / Multi-point BET
Efficiency 8 samples/hr
Adsorbate and Carrier Gas High purity nitrogen (99.999%)
High purity helium (99.999%)
Gas Mixing Control Mass Flow Controllers
Thermal Conductivity Detector 1
Analysis Ports 4 (3 if performing the reference method)
Range of BET Surface Area For reference method: 0.5 to 100 m²/g
For single BET and multipoint BET: 0.5 m²/g to infinity
Repeatability Typically, better than ±1.0% (carbon black)
Volume and Weight L 24.0 in (610 mm) × W 18.0 in (460 mm) × H 27.0 in (680 mm), 66 lbs (30 kg)
Power Requirements 110V or 200–240 VAC, 50/60 Hz, maximum power 300 W

Not sure if it’s the right instrument?

No worries, send us a sample and we will test it for you

Send a sample
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer
Morbi ornare magna nec tortor rutrum interdum. Donec interdum facilisis elit, et iaculis nunc facilisis vitae. Sed quis semper dolor, id efficitur ex.
Name of customer