Module Design for Minimal Dead Volume
The internal gas path design of the instrument adopts a unique integrated metal module design, which not only reduces the internal dead volume space but also lowers the system leakage rate.
Saturated Vapor Pressure P0
An independent P₀ pressure transducer is configured at 133 kPa for P₀ value testing, enabling real-time P/P₀ measurement for more accurate and reliable test data. Alternatively, an atmospheric pressure input method can be used to determine P₀.

Independent analysis ports
With independent analysis ports, the system employs a unique vacuum control logic that allows each station to operate without disruption, even when using a single mechanical pump or pump group. This enables simultaneous, independent experiments, meeting diverse adsorbent testing needs while ensuring high efficiency.
High-Precision Micropore Distribution Analysis (Micro 100C)
Utilizes advanced micropore models, including the Horvath-Kawazoe (HK) and Saito-Foley (SF) methods, to accurately determine pore size distribution. Ensures an aperture deviation of less than 0.02 nm, providing precise characterisation of microporous materials in gas adsorption studies.
Thermal Stabilisation
A core rod in the sample tube reduces dead volume and stabilizes the cold free space coefficient, while an iso-thermal jacket maintains a constant thermal profile along the tube. Additionally, automatic helium correction ensures precise calibration for any powder or particulate material, minimising temperature- related deviations during analysis.
Customisable Selection of Pressure Transducers
Depending on the model, the AMI-Micro 100 Series offers various quantities and types of pressure transducers. Among them, the Micro 100C, equipped with a 1 Torr transducer (selectable 0.1 Torr), enables a partial pressure (P/P₀) of up to 10⁻⁸ (N₂/77 K) in physical adsorption analysis.

Optimised Manifold Contamination Control
This system features a multi-channel, adjustable, and parallel vacuum design with segmented vacuum control. This setup effectively prevents samples from being drawn up into the analyser therefore preventing manifold contamination.
Turbo Molecular Pump
A Turbo Molecular pump is included on the Micro 100C. Achieving ultimate pressures of 10⁻⁸ Pa, this system ensures a solid foundation for precis micropore analysis at ultra- low pressures.
Multiple Degassing Stations for Sample Preparation
Equipped with two (2) integrated degassing ports and two (2) in-situ degassing ports. Each port offers independent temperature control from ambient to 400°C (Optional: RT-500°C), ensuring precise sample preparation. In- situ degassing enhances microporous material analysis by providing superior efficiency over ex- situ methods.